{"title":"JA-68","description":"\u003ch2\u003eService explanation for JA-68\u003c\/h2\u003e    \u003ch3\u003e1 The JA-68 universal output module\u003c\/h3\u003e    \u003cp\u003eThe JA-68 is a universal output module designed for the Jablotron systems of the JA-80 OASiS, JA-63 Profi and JA-65 Maestro series. The module provides eight factory pre-programmed semi-conductor outputs and a switch-over relay output. The relay can be configured using 10 DIP switches that allow you to command for multiple functions. There is no limit to the number of the JA-68 modules used in the system. The JA-68 can be combined with GSM, LAN or PSTN (landline) dialers.\u003cbr\u003e\u003cstrong\u003eThe module is designed to be placed in the housing of the PBX.\u003cbr\u003e  \u003cimg src=\"http:\/\/www.pg-securitysystems.nl\/images\/afbeelding%2078.jpg\" width=\"540\" height=\"360\"\u003e\u003c\/strong\u003e\u003c\/p\u003e    \u003ch3\u003e2 Semi-conductor outputs\u003c\/h3\u003e    \u003cp\u003eAll semi-conductor outputs are switchable to a common terminal marked \"C\". The switch ON\/OFF logic can be reversed by setting a jumper JP1 to the NC position (the default is NO).\u003c\/p\u003e    \u003cp\u003eDescription of the codes:\u003c\/p\u003e    \u003ctable border=\"0\"\u003e    \u003ctbody\u003e    \u003ctr\u003e    \u003ctd\u003e\u003cstrong\u003eCode \u003c\/strong\u003e\u003c\/td\u003e    \u003ctd\u003e\u003cstrong\u003e  Functie\u003c\/strong\u003e\u003c\/td\u003e    \u003c\/tr\u003e    \u003ctr\u003e    \u003ctd\u003e+U\u003c\/td\u003e    \u003ctd\u003e  Positive power supply of the digital bus (limited to 200 mA)\u003c\/td\u003e    \u003c\/tr\u003e    \u003ctr\u003e    \u003ctd\u003eGND\u003c\/td\u003e    \u003ctd\u003e  Negative pole of the power supply\u003c\/td\u003e    \u003c\/tr\u003e    \u003ctr\u003e    \u003ctd\u003eC\u003c\/td\u003e    \u003ctd\u003e  Common code (for all semi-conductor outputs)\u003c\/td\u003e    \u003c\/tr\u003e    \u003ctr\u003e    \u003ctd\u003eARM\u003c\/td\u003e    \u003ctd\u003e  All-set status (A or AB or ABC)\u003c\/td\u003e    \u003c\/tr\u003e    \u003ctr\u003e    \u003ctd\u003eALM\u003c\/td\u003e    \u003ctd\u003e  Burglar alarm\u003c\/td\u003e    \u003c\/tr\u003e    \u003ctr\u003e    \u003ctd\u003eFIR\u003c\/td\u003e    \u003ctd\u003e  Fire alarm\u003c\/td\u003e    \u003c\/tr\u003e    \u003ctr\u003e    \u003ctd\u003eTMP\u003c\/td\u003e    \u003ctd\u003e  Sabotage alarm\u003c\/td\u003e    \u003c\/tr\u003e    \u003ctr\u003e    \u003ctd\u003ePNC\u003c\/td\u003e    \u003ctd\u003e  Panic alarm\u003c\/td\u003e    \u003c\/tr\u003e    \u003ctr\u003e    \u003ctd\u003eFLT\u003c\/td\u003e    \u003ctd\u003e  Fault message (general faults, radio communication faults, backup battery faults\u003c\/td\u003e    \u003c\/tr\u003e    \u003ctr\u003e    \u003ctd\u003eAC\u003c\/td\u003e    \u003ctd\u003e  Socket (230V) power supply error\u003c\/td\u003e    \u003c\/tr\u003e    \u003ctr\u003e    \u003ctd\u003eLB\u003c\/td\u003e    \u003ctd\u003e  Low battery indication (applies to wireless devices, such as detectors, control panels, sirens or thermostats)\u003c\/td\u003e    \u003c\/tr\u003e    \u003c\/tbody\u003e    \u003c\/table\u003e    \u003cp\u003e\u003cem\u003eTabel 1\u003c\/em\u003e\u003c\/p\u003e    \u003ch3\u003e3 Relay configuration\u003c\/h3\u003e    \u003cp\u003eThe relay is configurable via a set of 10 DIP switches (see Table 2). The relay works with OR logic: It switches on if there is at least one activated preset function on it.\u003cbr\u003eExample: Setting switches 2,3,4 and 5 to ON causes the relay to indicate: burglary, fire, tamper or panic alarms. The relay switches ON when any of the four mentioned states of alarm are triggered.\u003c\/p\u003e    \u003cp\u003eDIP switches commands:\u003c\/p\u003e    \u003ctable border=\"0\"\u003e    \u003ctbody\u003e    \u003ctr\u003e    \u003ctd\u003e\u003cstrong\u003eNummer\u003c\/strong\u003e\u003c\/td\u003e    \u003ctd\u003e\u003cstrong\u003e  Label\u003c\/strong\u003e\u003c\/td\u003e    \u003ctd\u003e\u003cstrong\u003e  Functie\u003c\/strong\u003e\u003c\/td\u003e    \u003c\/tr\u003e    \u003ctr\u003e    \u003ctd\u003e1\u003c\/td\u003e    \u003ctd\u003e  ARM\u003c\/td\u003e    \u003ctd\u003e  All set\u003c\/td\u003e    \u003c\/tr\u003e    \u003ctr\u003e    \u003ctd\u003e2\u003c\/td\u003e    \u003ctd\u003e  ALM\u003c\/td\u003e    \u003ctd\u003e  Burglar alarm\u003c\/td\u003e    \u003c\/tr\u003e    \u003ctr\u003e    \u003ctd\u003e3\u003c\/td\u003e    \u003ctd\u003e  FIR\u003c\/td\u003e    \u003ctd\u003e  Fire alarm\u003c\/td\u003e    \u003c\/tr\u003e    \u003ctr\u003e    \u003ctd\u003e4\u003c\/td\u003e    \u003ctd\u003e  TMP\u003c\/td\u003e    \u003ctd\u003e  Sabotage alarm\u003c\/td\u003e    \u003c\/tr\u003e    \u003ctr\u003e    \u003ctd\u003e5\u003c\/td\u003e    \u003ctd\u003e  PNC\u003c\/td\u003e    \u003ctd\u003e  Panic alarm\u003c\/td\u003e    \u003c\/tr\u003e    \u003ctr\u003e    \u003ctd\u003e6\u003c\/td\u003e    \u003ctd\u003e  FLT\u003c\/td\u003e    \u003ctd\u003e  System disruption\u003c\/td\u003e    \u003c\/tr\u003e    \u003ctr\u003e    \u003ctd\u003e7\u003c\/td\u003e    \u003ctd\u003e  AC\u003c\/td\u003e    \u003ctd\u003e  Power supply error\u003c\/td\u003e    \u003c\/tr\u003e    \u003ctr\u003e    \u003ctd\u003e8\u003c\/td\u003e    \u003ctd\u003e  LB\u003c\/td\u003e    \u003ctd\u003e  Low battery\u003c\/td\u003e    \u003c\/tr\u003e    \u003ctr\u003e    \u003ctd\u003e9\u003c\/td\u003e    \u003ctd\u003e  PGX\u003c\/td\u003e    \u003ctd\u003e  Central PGX output\u003c\/td\u003e    \u003c\/tr\u003e    \u003ctr\u003e    \u003ctd\u003e10\u003c\/td\u003e    \u003ctd\u003e  PGY\u003c\/td\u003e    \u003ctd\u003e  Central PGY output\u003c\/td\u003e    \u003c\/tr\u003e    \u003c\/tbody\u003e    \u003c\/table\u003e    \u003cp\u003e\u003cem\u003eTabel 2\u003c\/em\u003e\u003c\/p\u003e    \u003cp style=\"text-align: justify;\"\u003eDescription of relay codes:\u003c\/p\u003e    \u003ctable border=\"0\"\u003e    \u003ctbody\u003e    \u003ctr\u003e    \u003ctd\u003e\u003cstrong\u003eLabel\u003c\/strong\u003e\u003c\/td\u003e    \u003ctd\u003e\u003cstrong\u003e  Beschrijving\u003c\/strong\u003e\u003c\/td\u003e    \u003c\/tr\u003e    \u003ctr\u003e    \u003ctd\u003e\u003cstrong\u003eNC\u003c\/strong\u003e\u003c\/td\u003e    \u003ctd\u003e  Normally closed relay\u003c\/td\u003e    \u003c\/tr\u003e    \u003ctr\u003e    \u003ctd\u003e\u003cstrong\u003eC\u003c\/strong\u003e\u003c\/td\u003e    \u003ctd\u003e  Common relay contact\u003c\/td\u003e    \u003c\/tr\u003e    \u003ctr\u003e    \u003ctd\u003e\u003cstrong\u003eNO\u003c\/strong\u003e\u003c\/td\u003e    \u003ctd\u003e  Normal open relay contact\u003c\/td\u003e    \u003c\/tr\u003e    \u003c\/tbody\u003e    \u003c\/table\u003e    \u003cem\u003eTable 3\u003c\/em\u003e  \u003cbr\u003e\u003cbr\u003e\u003cem\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e There is a minimum output activation time of 10 seconds for each of the 8 + 1 outputs\u003c\/em\u003e","products":[],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0701\/3315\/4025\/collections\/images.jpg?v=1738735573","url":"https:\/\/www.alarmsysteemexpert.nl\/en\/collections\/ja-68.oembed","provider":"alarmsysteemexpert","version":"1.0","type":"link"}